UOP 314-97

$143.50

Format: PDF      In Stock

 

Sale!
-50%

UOP 314-97

$143.50

Analysis of Refinery Waters for pH, Iron and Copper
standard by UOP LLC, A Honeywell Company, 01/01/1997

Format: PDF      In Stock

 

Category:

NOTE: Our website provide PDF immediately download, sometimes when the payment is processed and you did not receive the file, please feel free to connect with us.

Description

This method is for determining the pH of, and iron and copper concentrations in, refinery waters. The data may be used to gauge the extent of corrosion caused by refinery waters. Copper and iron are determined at levels of 0.1 µg/mL and higher using Atomic Absorption Spectrometry (AAS). The metals may be present as single dissolved ions, as complex ions with cyanide or other complexing agents, or as part of the suspended solids that are often present in such samples. Ammonia, hydrogen sulfide, hydrogen cyanide and organic matter do not interfere with this test. The pH of the water is determined because it usually correlates with the extent of corrosion.

Product Details

Published:
01/01/1997
Number of Pages:
7
File Size:
1 file , 170 KB